cam-bien-toc-do-series-a5s1-speed-sensors-series-a5s1.png

Differential-Hall-Effect Speed Sensors Ex ia (intrinsically safe) Series A5S1

To meet the specific requirements of hazardous areas we provide specialized types which are certified for ATEX/IECEx, as well as for other international standards such as UL/CSA and EAC (the Eurasian Customs Union with Russia, Kazakhstan, and Belarus). For Hazardous Areas (Zone 0-1) an intrinsically safe implementation in conjunction with our Isolating Barrier D461.

The correct choice of sensor is always a prerequisite to achieving a successful solution. Our A5S sensors are based on the proven Differential-Hall-Effect principle. Their low end of 0 Hz allows monitoring the machine down to zero speed. They are contact-free, wear-free, maintenance-free and unsusceptible versus external magnetic stray fields and machine vibration. These characteristics make the series of A5S sensors especially suited to all applications where high levels of accuracy and reliability are at a premium. In contrast, other sensors like magnet-inductive or static Hall-sensors do not meet these demands.

Virtually any steel profile can be detected: fine or coarse, helical or straight gear wheels, nuts or pole wheels with small or large cams. The speed range spans an area from a stationary state up to 25 000 pulses per second (0 Hz…25 kHz), depending on the application.

Each sensor in the series is available in various lengths and diameters and comes with a choice of connections. However, functionally all sensors have the same characteristics. The stainless steel sensor housing is sealed at the front and is pressure resistant (> 200 bars). A flat shaft is available or with a screw-in thread M12x1, M14x1, M14x1,5, M16x1, M16x1,5, M18x1, M18x1,5, M22x1, 5/8-18UNF-2A. Customized dimensions and thread specifications are possible.

A5S1DD0

Sensor A5S1DD0 for detection of rotational speed in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...25 kHz
  • Single Channel,
    the output displays the rotational speed as a single track frequency signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

 

 

A5S1DD3

Sensor A5S1DD3 for detection of rotational speed and direction of rotation in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...25 kHz
  • Dual Channel,
    1 track = rotational speed as frequency, 1 track = F/R status as binary signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

A5S1DD4

Sensor A5S1DD4 for detection of rotational speed and direction of rotation with two phase-shifted speed signals in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...25 kHz
  • Dual Channel,
    the output displays the rotational speed as a twin-track frequency signal (phase shifted)
  • Suitable for external direction detection with enhanced safety
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

A5S1DS0

Sensor A5S1DS0 for detection of rotational speed in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...12 kHz
  • Single Channel,
    the output displays the rotational speed as a single track frequency signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

 

A5S1DS3

Sensor A5S1DS3 for detection of rotational speed and direction of rotation in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...12 kHz
  • Dual Channel,
    1 track = rotational speed as frequency, 1 track = F/R status as binary signal
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

A5S1DS4

Sensor A5S1DS4 for detection of rotational speed and direction of rotation with two phase-shifted speed signals in Hazardous Areas Zone 0 or 1

  • Contact-free, wear-free, maintenance-free
  • Unsusceptible versus external magnetic stray fields and machine vibration
  • Suitable for all applications where high levels of accuracy and reliability are at a premium
  • Frequency range 0 Hz...12 kHz
  • Dual Channel,
    the output displays the rotational speed as a twin-track frequency signal (phase shifted)
  • Suitable for external direction detection with enhanced safety
  • TÜV certified for safety level SIL3 / IEC 61508:2010
  • TÜV certified for PL e; Cat. 3 / DIN EN ISO 13849-1:2016 + DIN EN ISO 13849-2:2012
  • TÜV certified for SILCL3 / IEC 62061:2015
  • Requires Isolating Barrier D461
  • For installation in Hazardous Areas as intrinsically safe operating resource
    • ATEX/IECEx certified for Ex ia IIC T4/T6 Ga
    • UL/CSA certified for Class I, Div 1, Groups A, B, C, D
    • EAC certified for Ex ia IIC T4/T6 Ga

D461R1

Isolating Barrier D461R1 for A5S1... Ex ia sensors in Hazardous Areas Zone 0-1

  • For use in connection with A5S1... Ex ia series sensors a highly efficient system for detecting rotational speed (and direction of rotation) in areas of explosion risk
  • Provides intrinsic safety for the sensor and its cabling
  • Enhanced output signal for use by electronic measuring devices
  • Implementation outside the Hazardous Area, resp. protected by a pressure resistant encapsulated housing
  • Certification
    • ATEX as Ex ia Ga IIC
    • IECEx as Ex ia Ga IIC
    • EAC as Ex ia Ga IIC